Optometry Research - Myopia, Optometric Practice, Therapy

Optometry Research Today is a free monthly online journal that collates and summarizes the latest research about Optometry, including details on myopia, optometric practice, therapy.


Optometry Research Today

Home

View Latest Issue

Information About Optometry

Books on Optometry

Advertising in Research Today

View Other Research Today Publications



An evaluation of the ConfoScan3 for corneal endothelial morphology analysis.

Sheng H, Parker EJ, Bullimore MA

The Ohio State University, College of Optometry, Columbus, Ohio, USA. sheng@chi.osu.edu

PURPOSE: We evaluated the ConfoScan3 confocal microscope and its associated software that allows automated analysis of the corneal endothelial morphology. METHODS: Images were taken on 30 normal subjects and 29 contact lens wearers with the Konan SP-9000 specular microscope and the ConfoScan3. The Konan images were analyzed with the KSS-300 software (center method). The Confoscan3 images were first analyzed with the automated method and then edited manually (semiautomated method). The agreement between methods was evaluated by calculating the difference between pairs of measurements, determining the mean and standard deviation of these differences, and the 95% limits of agreement. RESULTS: For normal subjects, all methods gave similar density values. The agreement with the Konan system was slightly better for the semiautomated method than the automated method. The automated method overestimated the degree of polymegethism (p < 0.001) and pleomorphism (p < 0.001). The semiautomated method showed substantial improvement. For contact lens wearers, agreement with the Konan system was poor for both automated and semiautomated methods. The automated method overestimated the degree of pleomorphism (p < 0.001) and the semiautomated method showed only modest improvement (p < 0.1). Both methods overestimated pleomorphism (automated p < 0.001; semiautomated p < 0.025). CONCLUSIONS: When using ConfoScan3 to evaluate the corneal endothelium of normal subjects, investigators should manually edit the processed images to achieve results comparable with the Konan system. When evaluating contact lens wearers, values from the ConfoScan3 are not interchangeable with those from the Konan system.

Published 17 September 2007 in Optom Vis Sci, 84(9): 888-95.
Full-text of this article is available online (may require subscription).

Place a permanent text-link or advertisement here for just US$15.

© 2005-2008 Optometry Research Today. All Rights Reserved.



Optometry Research Today Archive:

Volume 1 (2005)
  Issue 1 (October)
  Issue 2 (November)
  Issue 3 (December)

Volume 2 (2006)
  Issue 1 (January)
  Issue 2 (February)
  Issue 3 (March)
  Issue 4 (April)
  Issue 5 (May)
  Issue 6 (June)
  Issue 7 (July)
  Issue 8 (August)
  Issue 9 (September)
  Issue 10 (October)
  Issue 11 (November)
  Issue 12 (December)

Volume 3 (2007)
  Issue 1 (January)
  Issue 2 (February)
  Issue 3 (March)
  Issue 4 (April)
  Issue 5 (May)
  Issue 6 (June)
  Issue 7 (July)
  Issue 8 (August)
  Issue 9 (September)
  Issue 10 (October)
  Issue 11 (November)
  Issue 12 (December)

Volume 4 (2008)
  Issue 1 (January)
  Issue 2 (February)
  Issue 3 (March)
  Issue 4 (April)
  Issue 5 (May)



Optometry Books

How to Improve Your Child's Eyesight Naturally: A Thoughtful Parent's Guide

How to Improve Your Child's Eyesight Naturally: A Thoughtful Parent's Guide