Optometry Research - Myopia, Optometric Practice, Therapy

Optometry Research Today is a free monthly online journal that collates and summarizes the latest research about Optometry, including details on myopia, optometric practice, therapy.


Optometry Research Today

Home

View Latest Issue

Information About Optometry

Books on Optometry

Advertising in Research Today

View Other Research Today Publications



Frequency-Doubling Illusion under Scotopic Illumination and in Peripheral Vision.

Vallam K, Pataridis I, Metha AB

Department of Optometry and Vision Sciences, University of Melbourne, Carlton, Victoria, Australia.

PURPOSE: The authors sought to determine whether frequency-doubling illusion (FDI) could be perceived under scotopic illumination at central and peripheral retinal locations. For comparison, perception of the FDI at the central and peripheral retina under photopic illumination was also evaluated. METHODS: Five subjects matched the apparent spatial frequency of counterphase flickering sinusoidal gratings with stationary sinusoidal gratings presented foveally and out to 20 degrees eccentricity under photopic and scotopic illumination conditions. Two spatial frequencies (0.25 and 0.50 cpd) were used at four temporal frequencies (2, 8, 15, and 25 Hz). Subsequent experiments explored the range of spatial and temporal frequency stimulus conditions under which the scotopic FDI might be observed. RESULTS: Under scotopic illumination conditions, the apparent spatial frequency of eccentrically presented 0.25- and 0.50-cpd flickering gratings gradually increased as a function of flicker frequency and approaches "doubling" at 15 Hz. Under photopic conditions, the apparent spatial frequency of 0.25-cpd flickering at 25 Hz was approximately doubled in all four primary meridians at central and peripheral eccentricities. The final experiment showed that the spatiotemporal range under which the scotopic FDI could be seen was similar to the photopic illumination condition reported earlier. CONCLUSIONS: Scotopic FDI is similar to photopic FDI at the central and the peripheral retina. This suggests that similar mechanisms are responsible for generating the illusion under both photopic and scotopic illumination conditions.

Published 26 June 2007 in Invest Ophthalmol Vis Sci, 48(7): 3413-8.
Full-text of this article is available online (may require subscription).

Place a permanent text-link or advertisement here for just US$15.

© 2005-2008 Optometry Research Today. All Rights Reserved.



Optometry Research Today Archive:

Volume 1 (2005)
  Issue 1 (October)
  Issue 2 (November)
  Issue 3 (December)

Volume 2 (2006)
  Issue 1 (January)
  Issue 2 (February)
  Issue 3 (March)
  Issue 4 (April)
  Issue 5 (May)
  Issue 6 (June)
  Issue 7 (July)
  Issue 8 (August)
  Issue 9 (September)
  Issue 10 (October)
  Issue 11 (November)
  Issue 12 (December)

Volume 3 (2007)
  Issue 1 (January)
  Issue 2 (February)
  Issue 3 (March)
  Issue 4 (April)
  Issue 5 (May)
  Issue 6 (June)
  Issue 7 (July)
  Issue 8 (August)
  Issue 9 (September)
  Issue 10 (October)
  Issue 11 (November)
  Issue 12 (December)

Volume 4 (2008)
  Issue 1 (January)
  Issue 2 (February)
  Issue 3 (March)
  Issue 4 (April)
  Issue 5 (May)



Optometry Books

Clinical Anatomy of the Eye

Clinical Anatomy of the Eye