Optometry Research - Myopia, Optometric Practice, Therapy

Optometry Research Today is a free monthly online journal that collates and summarizes the latest research about Optometry, including details on myopia, optometric practice, therapy.


Optometry Research Today

Home

View Latest Issue

Information About Optometry

Books on Optometry

Advertising in Research Today

View Other Research Today Publications



Oxygen demands with hybrid contact lenses.

Pilskalns B, Fink BA, Hill RM

College of Optometry, The Ohio State University, Columbus, Ohio 43210, USA.

PURPOSE: The purpose of this study was to assess the corneal response, as measured by corneal oxygen uptake, of keratoconic corneas to SoftPerm and SynergEyes hybrid contact lenses at the central cornea, 2.0 and 4.5 mm temporal to the central cornea, and 1 mm temporal to the limbus. METHODS: Corneal oxygen uptake rates were measured with a Clark-type polarographic electrode on the right eyes of 14 subjects and the left eye of 1 subject, all with keratoconus. Measurements were made at the central cornea, 2.0 and 4.5 mm temporal to the central cornea, and 1 mm temporal to the limbus. They were made for the open eye condition, as well as following 300 s of SoftPerm and SynergEyes hybrid contact lens wear. A one-way analysis of variance (ANOVA) was used to determine the effect of measurement location on oxygen uptake rates under uncovered eye conditions. To determine the difference among oxygen uptake rates relative to those of the uncovered eye at each measurement location for each hybrid lens, a two-way repeated measures ANOVA was used. Multiple comparisons with Tukey-Kramer adjustment were used post hoc to determine which locations were significantly different. RESULTS: For the uncovered keratoconic cornea, there was no significant difference among the oxygen uptake rates associated with the three corneal locations; however, the oxygen uptake rates measured 1 mm temporal to the limbus were significantly higher than those measured at the three corneal locations. Comparison of oxygen uptake rates measured with the SoftPerm and SynergEyes lenses relative to those of the uncovered eye at each location revealed significantly higher rates at the peripheral cornea than at the central cornea. At all locations, the relative oxygen uptake rates obtained with the SynergEyes lenses were lower than those obtained with the SoftPerm lenses. CONCLUSIONS: The SynergEyes lens allows significantly more oxygen to reach the cornea during wear than the SoftPerm lens at the central cornea, as well as 2.0 mm and 4.5 mm temporal to the central cornea.

Published 16 April 2007 in Optom Vis Sci, 84(4): 334-42.
Full-text of this article is available online (may require subscription).

Place a permanent text-link or advertisement here for just US$15.

© 2005-2008 Optometry Research Today. All Rights Reserved.



Optometry Research Today Archive:

Volume 1 (2005)
  Issue 1 (October)
  Issue 2 (November)
  Issue 3 (December)

Volume 2 (2006)
  Issue 1 (January)
  Issue 2 (February)
  Issue 3 (March)
  Issue 4 (April)
  Issue 5 (May)
  Issue 6 (June)
  Issue 7 (July)
  Issue 8 (August)
  Issue 9 (September)
  Issue 10 (October)
  Issue 11 (November)
  Issue 12 (December)

Volume 3 (2007)
  Issue 1 (January)
  Issue 2 (February)
  Issue 3 (March)
  Issue 4 (April)
  Issue 5 (May)
  Issue 6 (June)
  Issue 7 (July)
  Issue 8 (August)
  Issue 9 (September)
  Issue 10 (October)
  Issue 11 (November)
  Issue 12 (December)

Volume 4 (2008)
  Issue 1 (January)
  Issue 2 (February)
  Issue 3 (March)
  Issue 4 (April)
  Issue 5 (May)



Optometry Books

Primary Care Optometry

Primary Care Optometry