Optometry Research - Myopia, Optometric Practice, Therapy

Optometry Research Today is a free monthly online journal that collates and summarizes the latest research about Optometry, including details on myopia, optometric practice, therapy.


Optometry Research Today

Home

View Latest Issue

Information About Optometry

Books on Optometry

Advertising in Research Today

View Other Research Today Publications



A new pattern electroretinogram paradigm evaluated in terms of user friendliness and agreement with perimetry.

Yang A, Swanson WH

State University of New York, State College of Optometry, New York, New York 10036, USA.

PURPOSE: To assess ease of use of the pattern electroretinogram optimized for glaucoma screening (PERGLA) paradigm by a novice operator; to study test-retest variability of the PERGLA parameters; and to compare results from the PERGLA to those from perimetry. DESIGN: Cohort study. PARTICIPANTS: Twelve healthy control subjects and 16 patients with moderate to advanced glaucoma in at least 1 eye. METHODS: Pattern electroretinograms were recorded simultaneously from both eyes using a commercially available testing station. Each participant underwent PERGLA procedures in 2 sessions. One eye of each subject was tested on contrast sensitivity perimetry (CSP) in which a 0.4 cycles/degree Gabor patch served as a stimulus. Central visual fields results from conventional automated perimetry (CAP) were obtained from patients' records. Bland-Altman analysis was performed on PERGLA results to assess normal test-retest variability. Differences from mean normal (in decibels [dB]) were compared for PERGLA versus CSP and CAP. MAIN OUTCOME MEASURES: Pattern electroretinogram amplitude, noise, phase, and test-retest variability (coefficient of variation); contrast sensitivity from CSP; perimetric sensitivity from CAP; and differences from mean normal for PERGLA, CSP, and CAP. RESULTS: The mean log amplitude (0.08+/-0.12 log muV) and the mean phase (1.92+/-0.07 pi rad) for the control group were consistent with published PERGLA norms, as was test-retest variability for both amplitude (coefficient of variation [CV] = 8.2+/-7.0%) and phase (CV = 1.1+/-0.9%). The mean signal-to-noise ratio (8.7+/-4.5) was lower than published norms. The test-retest variability increased as PERGLA log amplitude decreased (R2>0.12, P<0.05). On average, differences from mean normal were similar for PERGLA versus CSP and for PERGLA versus CAP (mean differences<0.5 dB) with 95% confidence intervals near +/-4 dB in both comparisons. CONCLUSIONS: A novice operator successfully replicated published PERGLA norms in a young control group for amplitude, phase, and repeatability. Higher test-retest variability was found in eyes with smaller signals. On average, PERGLA results were in reasonable agreement with those from perimetry, although there existed large individual differences which may limit the usage of PERGLA in screening or in following progression of glaucoma.

Published 2 April 2007 in Ophthalmology, 114(4): 671-9.
Full-text of this article is available online (may require subscription).

Place a permanent text-link or advertisement here for just US$15.

© 2005-2008 Optometry Research Today. All Rights Reserved.



Optometry Research Today Archive:

Volume 1 (2005)
  Issue 1 (October)
  Issue 2 (November)
  Issue 3 (December)

Volume 2 (2006)
  Issue 1 (January)
  Issue 2 (February)
  Issue 3 (March)
  Issue 4 (April)
  Issue 5 (May)
  Issue 6 (June)
  Issue 7 (July)
  Issue 8 (August)
  Issue 9 (September)
  Issue 10 (October)
  Issue 11 (November)
  Issue 12 (December)

Volume 3 (2007)
  Issue 1 (January)
  Issue 2 (February)
  Issue 3 (March)
  Issue 4 (April)
  Issue 5 (May)
  Issue 6 (June)
  Issue 7 (July)
  Issue 8 (August)
  Issue 9 (September)
  Issue 10 (October)
  Issue 11 (November)
  Issue 12 (December)

Volume 4 (2008)
  Issue 1 (January)
  Issue 2 (February)
  Issue 3 (March)
  Issue 4 (April)
  Issue 5 (May)



Optometry Books

Clinical Anatomy of the Eye

Clinical Anatomy of the Eye