Optometry Research - Myopia, Optometric Practice, Therapy

Optometry Research Today is a free monthly online journal that collates and summarizes the latest research about Optometry, including details on myopia, optometric practice, therapy.


Optometry Research Today

Home

View Latest Issue

Information About Optometry

Books on Optometry

Advertising in Research Today

View Other Research Today Publications



Simultaneous measurements of refraction and A-scan biometry during accommodation in humans.

Ostrin L, Kasthurirangan S, Win-Hall D, Glasser A

University of Houston College of Optometry, Houston, Texas 77004, USA.

PURPOSE: Accommodation is a dioptric change in power of the crystalline lens resulting from ciliary muscle contraction that leads to an increase in lens surface curvatures and thickness and changes in the position of lens surfaces. Previous studies have used A-scan ultrasound to measure changes in the position of lens surfaces with voluntary accommodation, but have not simultaneously measured the change in refraction. The goal of this study is to simultaneously measure and correlate refractive and biometric changes in the lens during voluntary accommodation in humans. METHODS: Refraction was measured off-axis in the right eye and biometry on-axis in the left eye simultaneously during voluntary accommodation in 22 human subjects between the ages of 21 and 30 years (mean +/- standard deviation: 25.8 +/- 2.3 years). Subjects viewed a distant target and four near targets spanning the full accommodative range available to evaluate refraction and lens surface position at each accommodative state. RESULTS: Maximum objectively measured accommodative amplitude of all subjects was 5.64 +/- 0.21 D (mean +/- standard error of mean). Biometric and refractive changes during accommodation were linearly correlated. The mean +/- standard error of mean decrease in anterior chamber depth was 0.051 +/- 0.008 mm/D, increase in lens thickness was 0.067 +/- 0.008 mm/D, and increase in anterior segment length was 0.017 +/- 0.005 mm/D during accommodation. There was a net anterior movement of the lens center of 0.017 +/- 0.005 mm/D. CONCLUSION: Anterior chamber depth, lens thickness, and anterior segment length change linearly with refraction during accommodation. Per-diopter changes in the lens were greater in the current study compared with previous studies in which only accommodative demand was measured, which overestimates the accommodative response.

Published 14 September 2006 in Optom Vis Sci, 83(9): 657-65.
Full-text of this article is available online (may require subscription).

Place a permanent text-link or advertisement here for just US$15.

© 2005-2008 Optometry Research Today. All Rights Reserved.



Optometry Research Today Archive:

Volume 1 (2005)
  Issue 1 (October)
  Issue 2 (November)
  Issue 3 (December)

Volume 2 (2006)
  Issue 1 (January)
  Issue 2 (February)
  Issue 3 (March)
  Issue 4 (April)
  Issue 5 (May)
  Issue 6 (June)
  Issue 7 (July)
  Issue 8 (August)
  Issue 9 (September)
  Issue 10 (October)
  Issue 11 (November)
  Issue 12 (December)

Volume 3 (2007)
  Issue 1 (January)
  Issue 2 (February)
  Issue 3 (March)
  Issue 4 (April)
  Issue 5 (May)
  Issue 6 (June)
  Issue 7 (July)
  Issue 8 (August)
  Issue 9 (September)
  Issue 10 (October)
  Issue 11 (November)
  Issue 12 (December)

Volume 4 (2008)
  Issue 1 (January)
  Issue 2 (February)
  Issue 3 (March)
  Issue 4 (April)
  Issue 5 (May)



Optometry Books

Primary Care Optometry

Primary Care Optometry